Hi Team,

 

We have encountered following defect in PROD environment. After which entire traffic got halted for around 10 minutes, we recently upgraded our cluster to Ignite 2.7.6 from 2.6.0.

Is this related to any existing open defect in this version? Has anyone observed the same defect earlier ?

 

Any help or pointers around this will be appreciated.

 

 

[2020-07-03T18:17:11,613][ERROR][sys-stripe-36-#37%CustomerCC%][G] Blocked system-critical thread has been detected. This can lead to cluster-wide undefined behaviour

[threadName=partition-exchanger, blockedFor=480s]

[2020-07-03T18:17:11,613][WARN ][sys-stripe-36-#37%CustomerCC%][G] Thread [name="exchange-worker-#344%CustomerCC%", id=391, state=TIMED_WAITING, blockCnt=1, waitCnt=2049782]

    Lock [object=java.util.concurrent.locks.AbstractQueuedSynchronizer$ConditionObject@6bf9f3a4, ownerName=null, ownerId=-1]

 

[2020-07-03T18:17:11,620][ERROR][sys-stripe-36-#37%CustomerCC%][] Critical system error detected. Will be handled accordingly to configured handler [hnd=StopNodeOrHaltFailureHandler [tryStop=false, timeout=0, super=AbstractFailureHandler [ignoredFailureTypes=[SYSTEM_WORKER_BLOCKED, SYSTEM_CRITICAL_OPERATION_TIMEOUT]]], failureCtx=FailureContext [type=SYSTEM_WORKER_BLOCKED, err=class o.a.i.IgniteException: GridWorker [name=partition-exchanger, igniteInstanceName=CustomerCC, finished=false, heartbeatTs=1593780431612]]]

org.apache.ignite.IgniteException: GridWorker [name=partition-exchanger, igniteInstanceName=CustomerCC, finished=false, heartbeatTs=1593780431612]

    at org.apache.ignite.internal.IgnitionEx$IgniteNamedInstance$2.apply(IgnitionEx.java:1831) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.IgnitionEx$IgniteNamedInstance$2.apply(IgnitionEx.java:1826) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.worker.WorkersRegistry.onIdle(WorkersRegistry.java:233) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.util.worker.GridWorker.onIdle(GridWorker.java:297) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.util.StripedExecutor$Stripe.body(StripedExecutor.java:513) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.util.worker.GridWorker.run(GridWorker.java:120) [ignite-core-2.7.6.jar:2.7.6]

    at java.lang.Thread.run(Thread.java:748) [?:1.8.0_151]

[2020-07-03T18:17:11,625][WARN ][sys-stripe-36-#37%CustomerCC%][FailureProcessor] No deadlocked threads detected.

[2020-07-03T18:17:21,790][INFO ][tcp-disco-sock-reader-#201%CustomerCC%][TcpDiscoverySpi] Finished serving remote node connection [rmtAddr=/xx.xx.xx.xx:46416, rmtPort=46416

[2020-07-03T18:17:21,793][WARN ][jvm-pause-detector-worker][IgniteKernal%CustomerCC] Possible too long JVM pause: 10133 milliseconds.

    [2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-31-#295%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:11764, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-57-#321%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:38500, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-5-#269%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:41442, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-53-#317%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:44178, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-59-#323%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:11884, writeTimeout=2000]

[2020-07-03T18:17:21,795][WARN ][grid-nio-worker-tcp-comm-59-#323%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:39044, writeTimeout=2000]

[2020-07-03T18:17:21,795][WARN ][grid-nio-worker-tcp-comm-53-#317%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:48756, writeTimeout=2000]

[2020-07-03T18:17:21,795][WARN ][grid-nio-worker-tcp-comm-59-#323%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:42190, writeTimeout=2000]

 

 

 

 

 

Thanks and Regards,

Kamlesh Joshi

 


"Confidentiality Warning: This message and any attachments are intended only for the use of the intended recipient(s), are confidential and may be privileged. If you are not the intended recipient, you are hereby notified that any review, re-transmission, conversion to hard copy, copying, circulation or other use of this message and any attachments is strictly prohibited. If you are not the intended recipient, please notify the sender immediately by return email and delete this message and any attachments from your system.

Virus Warning: Although the company has taken reasonable precautions to ensure no viruses are present in this email. The company cannot accept responsibility for any loss or damage arising from the use of this email or attachment."

stephendarlington stephendarlington
Reply | Threaded
Open this post in threaded view
|

Re: Ignite cluster became unresponsive

There are a few issues here — the blocked thread, the communication error — but I possibly the key one is the JVM pause:

[2020-07-03T18:17:21,793][WARN ][jvm-pause-detector-worker][IgniteKernal%CustomerCC] Possible too long JVM pause: 10133 milliseconds.

This is usually due to garbage collection, but there are a number of other possibilities such as slow I/O. Suggest you start with the recommendations on the GC tuning documentation page: https://apacheignite.readme.io/docs/jvm-and-system-tuning

Regards,
Stephen

On 4 Jul 2020, at 12:44, Kamlesh Joshi <[hidden email]> wrote:

Hi Team,
 
We have encountered following defect in PROD environment. After which entire traffic got halted for around 10 minutes, we recently upgraded our cluster to Ignite 2.7.6 from 2.6.0. 
Is this related to any existing open defect in this version? Has anyone observed the same defect earlier ?
 
Any help or pointers around this will be appreciated.
 
 
[2020-07-03T18:17:11,613][ERROR][sys-stripe-36-#37%CustomerCC%][G] Blocked system-critical thread has been detected. This can lead to cluster-wide undefined behaviour
[threadName=partition-exchanger, blockedFor=480s]
[2020-07-03T18:17:11,613][WARN ][sys-stripe-36-#37%CustomerCC%][G] Thread [name="exchange-worker-#344%CustomerCC%", id=391, state=TIMED_WAITING, blockCnt=1, waitCnt=2049782]
    Lock [object=java.util.concurrent.locks.AbstractQueuedSynchronizer$ConditionObject@6bf9f3a4, ownerName=null, ownerId=-1]
 
[2020-07-03T18:17:11,620][ERROR][sys-stripe-36-#37%CustomerCC%][] Critical system error detected. Will be handled accordingly to configured handler [hnd=StopNodeOrHaltFailureHandler [tryStop=false, timeout=0, super=AbstractFailureHandler [ignoredFailureTypes=[SYSTEM_WORKER_BLOCKED, SYSTEM_CRITICAL_OPERATION_TIMEOUT]]], failureCtx=FailureContext [type=SYSTEM_WORKER_BLOCKED, err=class o.a.i.IgniteException: GridWorker [name=partition-exchanger, igniteInstanceName=CustomerCC, finished=false, heartbeatTs=1593780431612]]]
org.apache.ignite.IgniteException: GridWorker [name=partition-exchanger, igniteInstanceName=CustomerCC, finished=false, heartbeatTs=1593780431612]
    at org.apache.ignite.internal.IgnitionEx$IgniteNamedInstance$2.apply(IgnitionEx.java:1831) [ignite-core-2.7.6.jar:2.7.6]
    at org.apache.ignite.internal.IgnitionEx$IgniteNamedInstance$2.apply(IgnitionEx.java:1826) [ignite-core-2.7.6.jar:2.7.6]
    at org.apache.ignite.internal.worker.WorkersRegistry.onIdle(WorkersRegistry.java:233) [ignite-core-2.7.6.jar:2.7.6]
    at org.apache.ignite.internal.util.worker.GridWorker.onIdle(GridWorker.java:297) [ignite-core-2.7.6.jar:2.7.6]
    at org.apache.ignite.internal.util.StripedExecutor$Stripe.body(StripedExecutor.java:513) [ignite-core-2.7.6.jar:2.7.6]
    at org.apache.ignite.internal.util.worker.GridWorker.run(GridWorker.java:120) [ignite-core-2.7.6.jar:2.7.6]
    at java.lang.Thread.run(Thread.java:748) [?:1.8.0_151]
[2020-07-03T18:17:11,625][WARN ][sys-stripe-36-#37%CustomerCC%][FailureProcessor] No deadlocked threads detected.
[2020-07-03T18:17:21,790][INFO ][tcp-disco-sock-reader-#201%CustomerCC%][TcpDiscoverySpi] Finished serving remote node connection [rmtAddr=/xx.xx.xx.xx:46416, rmtPort=46416
[2020-07-03T18:17:21,793][WARN ][jvm-pause-detector-worker][IgniteKernal%CustomerCC] Possible too long JVM pause: 10133 milliseconds.
    [2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-31-#295%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:11764, writeTimeout=2000]
[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-57-#321%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:38500, writeTimeout=2000]
[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-5-#269%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:41442, writeTimeout=2000]
[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-53-#317%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:44178, writeTimeout=2000]
[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-59-#323%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:11884, writeTimeout=2000]
[2020-07-03T18:17:21,795][WARN ][grid-nio-worker-tcp-comm-59-#323%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:39044, writeTimeout=2000]
[2020-07-03T18:17:21,795][WARN ][grid-nio-worker-tcp-comm-53-#317%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:48756, writeTimeout=2000]
[2020-07-03T18:17:21,795][WARN ][grid-nio-worker-tcp-comm-59-#323%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:42190, writeTimeout=2000]
 
 
 
 
 
Thanks and Regards,
Kamlesh Joshi
 


"Confidentiality Warning: This message and any attachments are intended only for the use of the intended recipient(s), are confidential and may be privileged. If you are not the intended recipient, you are hereby notified that any review, re-transmission, conversion to hard copy, copying, circulation or other use of this message and any attachments is strictly prohibited. If you are not the intended recipient, please notify the sender immediately by return email and delete this message and any attachments from your system.

Virus Warning: Although the company has taken reasonable precautions to ensure no viruses are present in this email. The company cannot accept responsibility for any loss or damage arising from the use of this email or attachment."



Kamlesh Joshi Kamlesh Joshi
Reply | Threaded
Open this post in threaded view
|

RE: [External]Re: Ignite cluster became unresponsive

Hi Stephen,

 

We have started our node with below JVM parameters. Also, we have increased these timeouts failureDetectionTimeout/clientFailureDetectionTimeout/networkTimeout to 480000.

 

-XX:+AggressiveOpts -XX:+AlwaysPreTouch -XX:+UseG1GC -XX:+ScavengeBeforeFullGC -XX:+DisableExplicitGC -XX:+UnlockCommercialFeatures -Djava.net.preferIPv4Stack=true -DIGNITE_LONG_OPERATIONS_DUMP_TIMEOUT=600000 -DIGNITE_THREAD_DUMP_ON_EXCHANGE_TIMEOUT=true -Dfile.encoding=UTF-8 -DIGNITE_QUIET=false

 

Is there anything else that we have to tune ?

 

And I think JVM pause is introduced as a result of the error that we encountered right? Correct me if am wrong.

 

Thanks and Regards,

Kamlesh Joshi

 

From: Stephen Darlington <[hidden email]>
Sent: 06 July 2020 14:09
To: user <[hidden email]>
Subject: [External]Re: Ignite cluster became unresponsive

 

The e-mail below is from an external source. Please do not open attachments or click links from an unknown or suspicious origin.


There are a few issues here — the blocked thread, the communication error — but I possibly the key one is the JVM pause:

 

[2020-07-03T18:17:21,793][WARN ][jvm-pause-detector-worker][IgniteKernal%CustomerCC] Possible too long JVM pause: 10133 milliseconds.

 

This is usually due to garbage collection, but there are a number of other possibilities such as slow I/O. Suggest you start with the recommendations on the GC tuning documentation page: https://apacheignite.readme.io/docs/jvm-and-system-tuning

 

Regards,

Stephen



On 4 Jul 2020, at 12:44, Kamlesh Joshi <[hidden email]> wrote:

 

Hi Team,

 

We have encountered following defect in PROD environment. After which entire traffic got halted for around 10 minutes, we recently upgraded our cluster to Ignite 2.7.6 from 2.6.0. 

Is this related to any existing open defect in this version? Has anyone observed the same defect earlier ?

 

Any help or pointers around this will be appreciated.

 

 

[2020-07-03T18:17:11,613][ERROR][sys-stripe-36-#37%CustomerCC%][G] Blocked system-critical thread has been detected. This can lead to cluster-wide undefined behaviour

[threadName=partition-exchanger, blockedFor=480s]

[2020-07-03T18:17:11,613][WARN ][sys-stripe-36-#37%CustomerCC%][G] Thread [name="exchange-worker-#344%CustomerCC%", id=391, state=TIMED_WAITING, blockCnt=1, waitCnt=2049782]

    Lock [object=java.util.concurrent.locks.AbstractQueuedSynchronizer$ConditionObject@6bf9f3a4, ownerName=null, ownerId=-1]

 

[2020-07-03T18:17:11,620][ERROR][sys-stripe-36-#37%CustomerCC%][] Critical system error detected. Will be handled accordingly to configured handler [hnd=StopNodeOrHaltFailureHandler [tryStop=false, timeout=0, super=AbstractFailureHandler [ignoredFailureTypes=[SYSTEM_WORKER_BLOCKED, SYSTEM_CRITICAL_OPERATION_TIMEOUT]]], failureCtx=FailureContext [type=SYSTEM_WORKER_BLOCKED, err=class o.a.i.IgniteException: GridWorker [name=partition-exchanger, igniteInstanceName=CustomerCC, finished=false, heartbeatTs=1593780431612]]]

org.apache.ignite.IgniteException: GridWorker [name=partition-exchanger, igniteInstanceName=CustomerCC, finished=false, heartbeatTs=1593780431612]

    at org.apache.ignite.internal.IgnitionEx$IgniteNamedInstance$2.apply(IgnitionEx.java:1831) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.IgnitionEx$IgniteNamedInstance$2.apply(IgnitionEx.java:1826) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.worker.WorkersRegistry.onIdle(WorkersRegistry.java:233) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.util.worker.GridWorker.onIdle(GridWorker.java:297) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.util.StripedExecutor$Stripe.body(StripedExecutor.java:513) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.util.worker.GridWorker.run(GridWorker.java:120) [ignite-core-2.7.6.jar:2.7.6]

    at java.lang.Thread.run(Thread.java:748) [?:1.8.0_151]

[2020-07-03T18:17:11,625][WARN ][sys-stripe-36-#37%CustomerCC%][FailureProcessor] No deadlocked threads detected.

[2020-07-03T18:17:21,790][INFO ][tcp-disco-sock-reader-#201%CustomerCC%][TcpDiscoverySpi] Finished serving remote node connection [rmtAddr=/xx.xx.xx.xx:46416, rmtPort=46416

[2020-07-03T18:17:21,793][WARN ][jvm-pause-detector-worker][IgniteKernal%CustomerCC] Possible too long JVM pause: 10133 milliseconds.

    [2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-31-#295%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:11764, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-57-#321%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:38500, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-5-#269%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:41442, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-53-#317%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:44178, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-59-#323%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:11884, writeTimeout=2000]

[2020-07-03T18:17:21,795][WARN ][grid-nio-worker-tcp-comm-59-#323%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:39044, writeTimeout=2000]

[2020-07-03T18:17:21,795][WARN ][grid-nio-worker-tcp-comm-53-#317%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:48756, writeTimeout=2000]

[2020-07-03T18:17:21,795][WARN ][grid-nio-worker-tcp-comm-59-#323%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:42190, writeTimeout=2000]

 

 

 

 

 

Thanks and Regards,

Kamlesh Joshi

 


"Confidentiality Warning: This message and any attachments are intended only for the use of the intended recipient(s), are confidential and may be privileged. If you are not the intended recipient, you are hereby notified that any review, re-transmission, conversion to hard copy, copying, circulation or other use of this message and any attachments is strictly prohibited. If you are not the intended recipient, please notify the sender immediately by return email and delete this message and any attachments from your system.

Virus Warning: Although the company has taken reasonable precautions to ensure no viruses are present in this email. The company cannot accept responsibility for any loss or damage arising from the use of this email or attachment."

 


"Confidentiality Warning: This message and any attachments are intended only for the use of the intended recipient(s), are confidential and may be privileged. If you are not the intended recipient, you are hereby notified that any review, re-transmission, conversion to hard copy, copying, circulation or other use of this message and any attachments is strictly prohibited. If you are not the intended recipient, please notify the sender immediately by return email and delete this message and any attachments from your system.

Virus Warning: Although the company has taken reasonable precautions to ensure no viruses are present in this email. The company cannot accept responsibility for any loss or damage arising from the use of this email or attachment."

Kamlesh Joshi Kamlesh Joshi
Reply | Threaded
Open this post in threaded view
|

RE: [External]Re: Ignite cluster became unresponsive

Hi Stephen/Team,

 

Did you got any chance to look into this?

 

Thanks and Regards,

Kamlesh Joshi

 

From: Kamlesh Joshi
Sent: 06 July 2020 14:50
To: [hidden email]
Subject: RE: [External]Re: Ignite cluster became unresponsive

 

Hi Stephen,

 

We have started our node with below JVM parameters. Also, we have increased these timeouts failureDetectionTimeout/clientFailureDetectionTimeout/networkTimeout to 480000.

 

-XX:+AggressiveOpts -XX:+AlwaysPreTouch -XX:+UseG1GC -XX:+ScavengeBeforeFullGC -XX:+DisableExplicitGC -XX:+UnlockCommercialFeatures -Djava.net.preferIPv4Stack=true -DIGNITE_LONG_OPERATIONS_DUMP_TIMEOUT=600000 -DIGNITE_THREAD_DUMP_ON_EXCHANGE_TIMEOUT=true -Dfile.encoding=UTF-8 -DIGNITE_QUIET=false

 

Is there anything else that we have to tune ?

 

And I think JVM pause is introduced as a result of the error that we encountered right? Correct me if am wrong.

 

Thanks and Regards,

Kamlesh Joshi

 

From: Stephen Darlington <[hidden email]>
Sent: 06 July 2020 14:09
To: user <[hidden email]>
Subject: [External]Re: Ignite cluster became unresponsive

 

The e-mail below is from an external source. Please do not open attachments or click links from an unknown or suspicious origin.

There are a few issues here — the blocked thread, the communication error — but I possibly the key one is the JVM pause:

 

[2020-07-03T18:17:21,793][WARN ][jvm-pause-detector-worker][IgniteKernal%CustomerCC] Possible too long JVM pause: 10133 milliseconds.

 

This is usually due to garbage collection, but there are a number of other possibilities such as slow I/O. Suggest you start with the recommendations on the GC tuning documentation page: https://apacheignite.readme.io/docs/jvm-and-system-tuning

 

Regards,

Stephen

 

On 4 Jul 2020, at 12:44, Kamlesh Joshi <[hidden email]> wrote:

 

Hi Team,

 

We have encountered following defect in PROD environment. After which entire traffic got halted for around 10 minutes, we recently upgraded our cluster to Ignite 2.7.6 from 2.6.0. 

Is this related to any existing open defect in this version? Has anyone observed the same defect earlier ?

 

Any help or pointers around this will be appreciated.

 

 

[2020-07-03T18:17:11,613][ERROR][sys-stripe-36-#37%CustomerCC%][G] Blocked system-critical thread has been detected. This can lead to cluster-wide undefined behaviour

[threadName=partition-exchanger, blockedFor=480s]

[2020-07-03T18:17:11,613][WARN ][sys-stripe-36-#37%CustomerCC%][G] Thread [name="exchange-worker-#344%CustomerCC%", id=391, state=TIMED_WAITING, blockCnt=1, waitCnt=2049782]

    Lock [object=java.util.concurrent.locks.AbstractQueuedSynchronizer$ConditionObject@6bf9f3a4, ownerName=null, ownerId=-1]

 

[2020-07-03T18:17:11,620][ERROR][sys-stripe-36-#37%CustomerCC%][] Critical system error detected. Will be handled accordingly to configured handler [hnd=StopNodeOrHaltFailureHandler [tryStop=false, timeout=0, super=AbstractFailureHandler [ignoredFailureTypes=[SYSTEM_WORKER_BLOCKED, SYSTEM_CRITICAL_OPERATION_TIMEOUT]]], failureCtx=FailureContext [type=SYSTEM_WORKER_BLOCKED, err=class o.a.i.IgniteException: GridWorker [name=partition-exchanger, igniteInstanceName=CustomerCC, finished=false, heartbeatTs=1593780431612]]]

org.apache.ignite.IgniteException: GridWorker [name=partition-exchanger, igniteInstanceName=CustomerCC, finished=false, heartbeatTs=1593780431612]

    at org.apache.ignite.internal.IgnitionEx$IgniteNamedInstance$2.apply(IgnitionEx.java:1831) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.IgnitionEx$IgniteNamedInstance$2.apply(IgnitionEx.java:1826) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.worker.WorkersRegistry.onIdle(WorkersRegistry.java:233) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.util.worker.GridWorker.onIdle(GridWorker.java:297) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.util.StripedExecutor$Stripe.body(StripedExecutor.java:513) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.util.worker.GridWorker.run(GridWorker.java:120) [ignite-core-2.7.6.jar:2.7.6]

    at java.lang.Thread.run(Thread.java:748) [?:1.8.0_151]

[2020-07-03T18:17:11,625][WARN ][sys-stripe-36-#37%CustomerCC%][FailureProcessor] No deadlocked threads detected.

[2020-07-03T18:17:21,790][INFO ][tcp-disco-sock-reader-#201%CustomerCC%][TcpDiscoverySpi] Finished serving remote node connection [rmtAddr=/xx.xx.xx.xx:46416, rmtPort=46416

[2020-07-03T18:17:21,793][WARN ][jvm-pause-detector-worker][IgniteKernal%CustomerCC] Possible too long JVM pause: 10133 milliseconds.

    [2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-31-#295%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:11764, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-57-#321%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:38500, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-5-#269%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:41442, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-53-#317%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:44178, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-59-#323%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:11884, writeTimeout=2000]

[2020-07-03T18:17:21,795][WARN ][grid-nio-worker-tcp-comm-59-#323%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:39044, writeTimeout=2000]

[2020-07-03T18:17:21,795][WARN ][grid-nio-worker-tcp-comm-53-#317%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:48756, writeTimeout=2000]

[2020-07-03T18:17:21,795][WARN ][grid-nio-worker-tcp-comm-59-#323%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:42190, writeTimeout=2000]

 

 

 

 

 

Thanks and Regards,

Kamlesh Joshi

 


"Confidentiality Warning: This message and any attachments are intended only for the use of the intended recipient(s), are confidential and may be privileged. If you are not the intended recipient, you are hereby notified that any review, re-transmission, conversion to hard copy, copying, circulation or other use of this message and any attachments is strictly prohibited. If you are not the intended recipient, please notify the sender immediately by return email and delete this message and any attachments from your system.

Virus Warning: Although the company has taken reasonable precautions to ensure no viruses are present in this email. The company cannot accept responsibility for any loss or damage arising from the use of this email or attachment."

 


"Confidentiality Warning: This message and any attachments are intended only for the use of the intended recipient(s), are confidential and may be privileged. If you are not the intended recipient, you are hereby notified that any review, re-transmission, conversion to hard copy, copying, circulation or other use of this message and any attachments is strictly prohibited. If you are not the intended recipient, please notify the sender immediately by return email and delete this message and any attachments from your system.

Virus Warning: Although the company has taken reasonable precautions to ensure no viruses are present in this email. The company cannot accept responsibility for any loss or damage arising from the use of this email or attachment."

ilya.kasnacheev ilya.kasnacheev
Reply | Threaded
Open this post in threaded view
|

Re: [External]Re: Ignite cluster became unresponsive

Hello!

Can you provide full thread dump (jstack) after you see these messages?

Regards,
--
Ilya Kasnacheev


ср, 8 июл. 2020 г. в 15:57, Kamlesh Joshi <[hidden email]>:

Hi Stephen/Team,

 

Did you got any chance to look into this?

 

Thanks and Regards,

Kamlesh Joshi

 

From: Kamlesh Joshi
Sent: 06 July 2020 14:50
To: [hidden email]
Subject: RE: [External]Re: Ignite cluster became unresponsive

 

Hi Stephen,

 

We have started our node with below JVM parameters. Also, we have increased these timeouts failureDetectionTimeout/clientFailureDetectionTimeout/networkTimeout to 480000.

 

-XX:+AggressiveOpts -XX:+AlwaysPreTouch -XX:+UseG1GC -XX:+ScavengeBeforeFullGC -XX:+DisableExplicitGC -XX:+UnlockCommercialFeatures -Djava.net.preferIPv4Stack=true -DIGNITE_LONG_OPERATIONS_DUMP_TIMEOUT=600000 -DIGNITE_THREAD_DUMP_ON_EXCHANGE_TIMEOUT=true -Dfile.encoding=UTF-8 -DIGNITE_QUIET=false

 

Is there anything else that we have to tune ?

 

And I think JVM pause is introduced as a result of the error that we encountered right? Correct me if am wrong.

 

Thanks and Regards,

Kamlesh Joshi

 

From: Stephen Darlington <[hidden email]>
Sent: 06 July 2020 14:09
To: user <[hidden email]>
Subject: [External]Re: Ignite cluster became unresponsive

 

The e-mail below is from an external source. Please do not open attachments or click links from an unknown or suspicious origin.

There are a few issues here — the blocked thread, the communication error — but I possibly the key one is the JVM pause:

 

[2020-07-03T18:17:21,793][WARN ][jvm-pause-detector-worker][IgniteKernal%CustomerCC] Possible too long JVM pause: 10133 milliseconds.

 

This is usually due to garbage collection, but there are a number of other possibilities such as slow I/O. Suggest you start with the recommendations on the GC tuning documentation page: https://apacheignite.readme.io/docs/jvm-and-system-tuning

 

Regards,

Stephen

 

On 4 Jul 2020, at 12:44, Kamlesh Joshi <[hidden email]> wrote:

 

Hi Team,

 

We have encountered following defect in PROD environment. After which entire traffic got halted for around 10 minutes, we recently upgraded our cluster to Ignite 2.7.6 from 2.6.0. 

Is this related to any existing open defect in this version? Has anyone observed the same defect earlier ?

 

Any help or pointers around this will be appreciated.

 

 

[2020-07-03T18:17:11,613][ERROR][sys-stripe-36-#37%CustomerCC%][G] Blocked system-critical thread has been detected. This can lead to cluster-wide undefined behaviour

[threadName=partition-exchanger, blockedFor=480s]

[2020-07-03T18:17:11,613][WARN ][sys-stripe-36-#37%CustomerCC%][G] Thread [name="exchange-worker-#344%CustomerCC%", id=391, state=TIMED_WAITING, blockCnt=1, waitCnt=2049782]

    Lock [object=java.util.concurrent.locks.AbstractQueuedSynchronizer$ConditionObject@6bf9f3a4, ownerName=null, ownerId=-1]

 

[2020-07-03T18:17:11,620][ERROR][sys-stripe-36-#37%CustomerCC%][] Critical system error detected. Will be handled accordingly to configured handler [hnd=StopNodeOrHaltFailureHandler [tryStop=false, timeout=0, super=AbstractFailureHandler [ignoredFailureTypes=[SYSTEM_WORKER_BLOCKED, SYSTEM_CRITICAL_OPERATION_TIMEOUT]]], failureCtx=FailureContext [type=SYSTEM_WORKER_BLOCKED, err=class o.a.i.IgniteException: GridWorker [name=partition-exchanger, igniteInstanceName=CustomerCC, finished=false, heartbeatTs=1593780431612]]]

org.apache.ignite.IgniteException: GridWorker [name=partition-exchanger, igniteInstanceName=CustomerCC, finished=false, heartbeatTs=1593780431612]

    at org.apache.ignite.internal.IgnitionEx$IgniteNamedInstance$2.apply(IgnitionEx.java:1831) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.IgnitionEx$IgniteNamedInstance$2.apply(IgnitionEx.java:1826) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.worker.WorkersRegistry.onIdle(WorkersRegistry.java:233) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.util.worker.GridWorker.onIdle(GridWorker.java:297) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.util.StripedExecutor$Stripe.body(StripedExecutor.java:513) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.util.worker.GridWorker.run(GridWorker.java:120) [ignite-core-2.7.6.jar:2.7.6]

    at java.lang.Thread.run(Thread.java:748) [?:1.8.0_151]

[2020-07-03T18:17:11,625][WARN ][sys-stripe-36-#37%CustomerCC%][FailureProcessor] No deadlocked threads detected.

[2020-07-03T18:17:21,790][INFO ][tcp-disco-sock-reader-#201%CustomerCC%][TcpDiscoverySpi] Finished serving remote node connection [rmtAddr=/xx.xx.xx.xx:46416, rmtPort=46416

[2020-07-03T18:17:21,793][WARN ][jvm-pause-detector-worker][IgniteKernal%CustomerCC] Possible too long JVM pause: 10133 milliseconds.

    [2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-31-#295%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:11764, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-57-#321%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:38500, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-5-#269%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:41442, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-53-#317%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:44178, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-59-#323%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:11884, writeTimeout=2000]

[2020-07-03T18:17:21,795][WARN ][grid-nio-worker-tcp-comm-59-#323%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:39044, writeTimeout=2000]

[2020-07-03T18:17:21,795][WARN ][grid-nio-worker-tcp-comm-53-#317%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:48756, writeTimeout=2000]

[2020-07-03T18:17:21,795][WARN ][grid-nio-worker-tcp-comm-59-#323%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:42190, writeTimeout=2000]

 

 

 

 

 

Thanks and Regards,

Kamlesh Joshi

 


"Confidentiality Warning: This message and any attachments are intended only for the use of the intended recipient(s), are confidential and may be privileged. If you are not the intended recipient, you are hereby notified that any review, re-transmission, conversion to hard copy, copying, circulation or other use of this message and any attachments is strictly prohibited. If you are not the intended recipient, please notify the sender immediately by return email and delete this message and any attachments from your system.

Virus Warning: Although the company has taken reasonable precautions to ensure no viruses are present in this email. The company cannot accept responsibility for any loss or damage arising from the use of this email or attachment."

 


"Confidentiality Warning: This message and any attachments are intended only for the use of the intended recipient(s), are confidential and may be privileged. If you are not the intended recipient, you are hereby notified that any review, re-transmission, conversion to hard copy, copying, circulation or other use of this message and any attachments is strictly prohibited. If you are not the intended recipient, please notify the sender immediately by return email and delete this message and any attachments from your system.

Virus Warning: Although the company has taken reasonable precautions to ensure no viruses are present in this email. The company cannot accept responsibility for any loss or damage arising from the use of this email or attachment."

Kamlesh Joshi Kamlesh Joshi
Reply | Threaded
Open this post in threaded view
|

RE: [External]Re: Ignite cluster became unresponsive

Hi Ilya,

 

PFA the entire node logs, which contains thread dump as well. Let us know if any findings.

 

Thanks and Regards,

Kamlesh Joshi

 

From: Ilya Kasnacheev <[hidden email]>
Sent: 10 July 2020 17:51
To: [hidden email]
Subject: Re: [External]Re: Ignite cluster became unresponsive

 

The e-mail below is from an external source. Please do not open attachments or click links from an unknown or suspicious origin.

Hello!

 

Can you provide full thread dump (jstack) after you see these messages?

 

Regards,

--

Ilya Kasnacheev

 

 

ср, 8 июл. 2020 г. в 15:57, Kamlesh Joshi <[hidden email]>:

Hi Stephen/Team,

 

Did you got any chance to look into this?

 

Thanks and Regards,

Kamlesh Joshi

 

From: Kamlesh Joshi
Sent: 06 July 2020 14:50
To: [hidden email]
Subject: RE: [External]Re: Ignite cluster became unresponsive

 

Hi Stephen,

 

We have started our node with below JVM parameters. Also, we have increased these timeouts failureDetectionTimeout/clientFailureDetectionTimeout/networkTimeout to 480000.

 

-XX:+AggressiveOpts -XX:+AlwaysPreTouch -XX:+UseG1GC -XX:+ScavengeBeforeFullGC -XX:+DisableExplicitGC -XX:+UnlockCommercialFeatures -Djava.net.preferIPv4Stack=true -DIGNITE_LONG_OPERATIONS_DUMP_TIMEOUT=600000 -DIGNITE_THREAD_DUMP_ON_EXCHANGE_TIMEOUT=true -Dfile.encoding=UTF-8 -DIGNITE_QUIET=false

 

Is there anything else that we have to tune ?

 

And I think JVM pause is introduced as a result of the error that we encountered right? Correct me if am wrong.

 

Thanks and Regards,

Kamlesh Joshi

 

From: Stephen Darlington <[hidden email]>
Sent: 06 July 2020 14:09
To: user <[hidden email]>
Subject: [External]Re: Ignite cluster became unresponsive

 

The e-mail below is from an external source. Please do not open attachments or click links from an unknown or suspicious origin.

There are a few issues here — the blocked thread, the communication error — but I possibly the key one is the JVM pause:

 

[2020-07-03T18:17:21,793][WARN ][jvm-pause-detector-worker][IgniteKernal%CustomerCC] Possible too long JVM pause: 10133 milliseconds.

 

This is usually due to garbage collection, but there are a number of other possibilities such as slow I/O. Suggest you start with the recommendations on the GC tuning documentation page: https://apacheignite.readme.io/docs/jvm-and-system-tuning

 

Regards,

Stephen

 

On 4 Jul 2020, at 12:44, Kamlesh Joshi <[hidden email]> wrote:

 

Hi Team,

 

We have encountered following defect in PROD environment. After which entire traffic got halted for around 10 minutes, we recently upgraded our cluster to Ignite 2.7.6 from 2.6.0. 

Is this related to any existing open defect in this version? Has anyone observed the same defect earlier ?

 

Any help or pointers around this will be appreciated.

 

 

[2020-07-03T18:17:11,613][ERROR][sys-stripe-36-#37%CustomerCC%][G] Blocked system-critical thread has been detected. This can lead to cluster-wide undefined behaviour

[threadName=partition-exchanger, blockedFor=480s]

[2020-07-03T18:17:11,613][WARN ][sys-stripe-36-#37%CustomerCC%][G] Thread [name="exchange-worker-#344%CustomerCC%", id=391, state=TIMED_WAITING, blockCnt=1, waitCnt=2049782]

    Lock [object=java.util.concurrent.locks.AbstractQueuedSynchronizer$ConditionObject@6bf9f3a4, ownerName=null, ownerId=-1]

 

[2020-07-03T18:17:11,620][ERROR][sys-stripe-36-#37%CustomerCC%][] Critical system error detected. Will be handled accordingly to configured handler [hnd=StopNodeOrHaltFailureHandler [tryStop=false, timeout=0, super=AbstractFailureHandler [ignoredFailureTypes=[SYSTEM_WORKER_BLOCKED, SYSTEM_CRITICAL_OPERATION_TIMEOUT]]], failureCtx=FailureContext [type=SYSTEM_WORKER_BLOCKED, err=class o.a.i.IgniteException: GridWorker [name=partition-exchanger, igniteInstanceName=CustomerCC, finished=false, heartbeatTs=1593780431612]]]

org.apache.ignite.IgniteException: GridWorker [name=partition-exchanger, igniteInstanceName=CustomerCC, finished=false, heartbeatTs=1593780431612]

    at org.apache.ignite.internal.IgnitionEx$IgniteNamedInstance$2.apply(IgnitionEx.java:1831) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.IgnitionEx$IgniteNamedInstance$2.apply(IgnitionEx.java:1826) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.worker.WorkersRegistry.onIdle(WorkersRegistry.java:233) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.util.worker.GridWorker.onIdle(GridWorker.java:297) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.util.StripedExecutor$Stripe.body(StripedExecutor.java:513) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.util.worker.GridWorker.run(GridWorker.java:120) [ignite-core-2.7.6.jar:2.7.6]

    at java.lang.Thread.run(Thread.java:748) [?:1.8.0_151]

[2020-07-03T18:17:11,625][WARN ][sys-stripe-36-#37%CustomerCC%][FailureProcessor] No deadlocked threads detected.

[2020-07-03T18:17:21,790][INFO ][tcp-disco-sock-reader-#201%CustomerCC%][TcpDiscoverySpi] Finished serving remote node connection [rmtAddr=/xx.xx.xx.xx:46416, rmtPort=46416

[2020-07-03T18:17:21,793][WARN ][jvm-pause-detector-worker][IgniteKernal%CustomerCC] Possible too long JVM pause: 10133 milliseconds.

    [2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-31-#295%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:11764, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-57-#321%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:38500, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-5-#269%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:41442, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-53-#317%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:44178, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-59-#323%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:11884, writeTimeout=2000]

[2020-07-03T18:17:21,795][WARN ][grid-nio-worker-tcp-comm-59-#323%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:39044, writeTimeout=2000]

[2020-07-03T18:17:21,795][WARN ][grid-nio-worker-tcp-comm-53-#317%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:48756, writeTimeout=2000]

[2020-07-03T18:17:21,795][WARN ][grid-nio-worker-tcp-comm-59-#323%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:42190, writeTimeout=2000]

 

 

 

 

 

Thanks and Regards,

Kamlesh Joshi

 


"Confidentiality Warning: This message and any attachments are intended only for the use of the intended recipient(s), are confidential and may be privileged. If you are not the intended recipient, you are hereby notified that any review, re-transmission, conversion to hard copy, copying, circulation or other use of this message and any attachments is strictly prohibited. If you are not the intended recipient, please notify the sender immediately by return email and delete this message and any attachments from your system.

Virus Warning: Although the company has taken reasonable precautions to ensure no viruses are present in this email. The company cannot accept responsibility for any loss or damage arising from the use of this email or attachment."

 


"Confidentiality Warning: This message and any attachments are intended only for the use of the intended recipient(s), are confidential and may be privileged. If you are not the intended recipient, you are hereby notified that any review, re-transmission, conversion to hard copy, copying, circulation or other use of this message and any attachments is strictly prohibited. If you are not the intended recipient, please notify the sender immediately by return email and delete this message and any attachments from your system.

Virus Warning: Although the company has taken reasonable precautions to ensure no viruses are present in this email. The company cannot accept responsibility for any loss or damage arising from the use of this email or attachment."


"Confidentiality Warning: This message and any attachments are intended only for the use of the intended recipient(s), are confidential and may be privileged. If you are not the intended recipient, you are hereby notified that any review, re-transmission, conversion to hard copy, copying, circulation or other use of this message and any attachments is strictly prohibited. If you are not the intended recipient, please notify the sender immediately by return email and delete this message and any attachments from your system.

Virus Warning: Although the company has taken reasonable precautions to ensure no viruses are present in this email. The company cannot accept responsibility for any loss or damage arising from the use of this email or attachment."


ignite-2020-07-03.zip (3M) Download Attachment
ilya.kasnacheev ilya.kasnacheev
Reply | Threaded
Open this post in threaded view
|

Re: [External]Re: Ignite cluster became unresponsive

Hello!

It seems that communication connections were closed after CG pause, then you have got half-open connections. It is recommended to keep socketWriteTimeout and failure detection timeout in relative sync.

Default socketWriteTimeout on TcpConnectionSpi is very low while your failure detection timeout is rather high, leading to such issue.

It is also possible that client nodes can connect to a server node but not vice versa, leading to failure of opening connections once they are closed:

Thread [name="sys-stripe-12-#13%EDIFCustomerCC%", id=45, state=RUNNABLE, blockCnt=851, waitCnt=27526057]
        at sun.nio.ch.Net.poll(Native Method)
        at sun.nio.ch.SocketChannelImpl.poll(SocketChannelImpl.java:954)
        at sun.nio.ch.SocketAdaptor.connect(SocketAdaptor.java:110)
        at o.a.i.spi.communication.tcp.TcpCommunicationSpi.createTcpClient(TcpCommunicationSpi.java:3299)
        at o.a.i.spi.communication.tcp.TcpCommunicationSpi.createNioClient(TcpCommunicationSpi.java:2987)
        at o.a.i.spi.communication.tcp.TcpCommunicationSpi.reserveClient(TcpCommunicationSpi.java:2870)
        at o.a.i.spi.communication.tcp.TcpCommunicationSpi.sendMessage0(TcpCommunicationSpi.java:2713)
        at o.a.i.spi.communication.tcp.TcpCommunicationSpi.sendMessage(TcpCommunicationSpi.java:2672)


Regards,
--
Ilya Kasnacheev


пт, 10 июл. 2020 г. в 16:32, Kamlesh Joshi <[hidden email]>:

Hi Ilya,

 

PFA the entire node logs, which contains thread dump as well. Let us know if any findings.

 

Thanks and Regards,

Kamlesh Joshi

 

From: Ilya Kasnacheev <[hidden email]>
Sent: 10 July 2020 17:51
To: [hidden email]
Subject: Re: [External]Re: Ignite cluster became unresponsive

 

The e-mail below is from an external source. Please do not open attachments or click links from an unknown or suspicious origin.

Hello!

 

Can you provide full thread dump (jstack) after you see these messages?

 

Regards,

--

Ilya Kasnacheev

 

 

ср, 8 июл. 2020 г. в 15:57, Kamlesh Joshi <[hidden email]>:

Hi Stephen/Team,

 

Did you got any chance to look into this?

 

Thanks and Regards,

Kamlesh Joshi

 

From: Kamlesh Joshi
Sent: 06 July 2020 14:50
To: [hidden email]
Subject: RE: [External]Re: Ignite cluster became unresponsive

 

Hi Stephen,

 

We have started our node with below JVM parameters. Also, we have increased these timeouts failureDetectionTimeout/clientFailureDetectionTimeout/networkTimeout to 480000.

 

-XX:+AggressiveOpts -XX:+AlwaysPreTouch -XX:+UseG1GC -XX:+ScavengeBeforeFullGC -XX:+DisableExplicitGC -XX:+UnlockCommercialFeatures -Djava.net.preferIPv4Stack=true -DIGNITE_LONG_OPERATIONS_DUMP_TIMEOUT=600000 -DIGNITE_THREAD_DUMP_ON_EXCHANGE_TIMEOUT=true -Dfile.encoding=UTF-8 -DIGNITE_QUIET=false

 

Is there anything else that we have to tune ?

 

And I think JVM pause is introduced as a result of the error that we encountered right? Correct me if am wrong.

 

Thanks and Regards,

Kamlesh Joshi

 

From: Stephen Darlington <[hidden email]>
Sent: 06 July 2020 14:09
To: user <[hidden email]>
Subject: [External]Re: Ignite cluster became unresponsive

 

The e-mail below is from an external source. Please do not open attachments or click links from an unknown or suspicious origin.

There are a few issues here — the blocked thread, the communication error — but I possibly the key one is the JVM pause:

 

[2020-07-03T18:17:21,793][WARN ][jvm-pause-detector-worker][IgniteKernal%CustomerCC] Possible too long JVM pause: 10133 milliseconds.

 

This is usually due to garbage collection, but there are a number of other possibilities such as slow I/O. Suggest you start with the recommendations on the GC tuning documentation page: https://apacheignite.readme.io/docs/jvm-and-system-tuning

 

Regards,

Stephen

 

On 4 Jul 2020, at 12:44, Kamlesh Joshi <[hidden email]> wrote:

 

Hi Team,

 

We have encountered following defect in PROD environment. After which entire traffic got halted for around 10 minutes, we recently upgraded our cluster to Ignite 2.7.6 from 2.6.0. 

Is this related to any existing open defect in this version? Has anyone observed the same defect earlier ?

 

Any help or pointers around this will be appreciated.

 

 

[2020-07-03T18:17:11,613][ERROR][sys-stripe-36-#37%CustomerCC%][G] Blocked system-critical thread has been detected. This can lead to cluster-wide undefined behaviour

[threadName=partition-exchanger, blockedFor=480s]

[2020-07-03T18:17:11,613][WARN ][sys-stripe-36-#37%CustomerCC%][G] Thread [name="exchange-worker-#344%CustomerCC%", id=391, state=TIMED_WAITING, blockCnt=1, waitCnt=2049782]

    Lock [object=java.util.concurrent.locks.AbstractQueuedSynchronizer$ConditionObject@6bf9f3a4, ownerName=null, ownerId=-1]

 

[2020-07-03T18:17:11,620][ERROR][sys-stripe-36-#37%CustomerCC%][] Critical system error detected. Will be handled accordingly to configured handler [hnd=StopNodeOrHaltFailureHandler [tryStop=false, timeout=0, super=AbstractFailureHandler [ignoredFailureTypes=[SYSTEM_WORKER_BLOCKED, SYSTEM_CRITICAL_OPERATION_TIMEOUT]]], failureCtx=FailureContext [type=SYSTEM_WORKER_BLOCKED, err=class o.a.i.IgniteException: GridWorker [name=partition-exchanger, igniteInstanceName=CustomerCC, finished=false, heartbeatTs=1593780431612]]]

org.apache.ignite.IgniteException: GridWorker [name=partition-exchanger, igniteInstanceName=CustomerCC, finished=false, heartbeatTs=1593780431612]

    at org.apache.ignite.internal.IgnitionEx$IgniteNamedInstance$2.apply(IgnitionEx.java:1831) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.IgnitionEx$IgniteNamedInstance$2.apply(IgnitionEx.java:1826) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.worker.WorkersRegistry.onIdle(WorkersRegistry.java:233) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.util.worker.GridWorker.onIdle(GridWorker.java:297) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.util.StripedExecutor$Stripe.body(StripedExecutor.java:513) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.util.worker.GridWorker.run(GridWorker.java:120) [ignite-core-2.7.6.jar:2.7.6]

    at java.lang.Thread.run(Thread.java:748) [?:1.8.0_151]

[2020-07-03T18:17:11,625][WARN ][sys-stripe-36-#37%CustomerCC%][FailureProcessor] No deadlocked threads detected.

[2020-07-03T18:17:21,790][INFO ][tcp-disco-sock-reader-#201%CustomerCC%][TcpDiscoverySpi] Finished serving remote node connection [rmtAddr=/xx.xx.xx.xx:46416, rmtPort=46416

[2020-07-03T18:17:21,793][WARN ][jvm-pause-detector-worker][IgniteKernal%CustomerCC] Possible too long JVM pause: 10133 milliseconds.

    [2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-31-#295%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:11764, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-57-#321%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:38500, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-5-#269%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:41442, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-53-#317%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:44178, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-59-#323%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:11884, writeTimeout=2000]

[2020-07-03T18:17:21,795][WARN ][grid-nio-worker-tcp-comm-59-#323%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:39044, writeTimeout=2000]

[2020-07-03T18:17:21,795][WARN ][grid-nio-worker-tcp-comm-53-#317%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:48756, writeTimeout=2000]

[2020-07-03T18:17:21,795][WARN ][grid-nio-worker-tcp-comm-59-#323%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:42190, writeTimeout=2000]

 

 

 

 

 

Thanks and Regards,

Kamlesh Joshi

 


"Confidentiality Warning: This message and any attachments are intended only for the use of the intended recipient(s), are confidential and may be privileged. If you are not the intended recipient, you are hereby notified that any review, re-transmission, conversion to hard copy, copying, circulation or other use of this message and any attachments is strictly prohibited. If you are not the intended recipient, please notify the sender immediately by return email and delete this message and any attachments from your system.

Virus Warning: Although the company has taken reasonable precautions to ensure no viruses are present in this email. The company cannot accept responsibility for any loss or damage arising from the use of this email or attachment."

 


"Confidentiality Warning: This message and any attachments are intended only for the use of the intended recipient(s), are confidential and may be privileged. If you are not the intended recipient, you are hereby notified that any review, re-transmission, conversion to hard copy, copying, circulation or other use of this message and any attachments is strictly prohibited. If you are not the intended recipient, please notify the sender immediately by return email and delete this message and any attachments from your system.

Virus Warning: Although the company has taken reasonable precautions to ensure no viruses are present in this email. The company cannot accept responsibility for any loss or damage arising from the use of this email or attachment."


"Confidentiality Warning: This message and any attachments are intended only for the use of the intended recipient(s), are confidential and may be privileged. If you are not the intended recipient, you are hereby notified that any review, re-transmission, conversion to hard copy, copying, circulation or other use of this message and any attachments is strictly prohibited. If you are not the intended recipient, please notify the sender immediately by return email and delete this message and any attachments from your system.

Virus Warning: Although the company has taken reasonable precautions to ensure no viruses are present in this email. The company cannot accept responsibility for any loss or damage arising from the use of this email or attachment."

Kamlesh Joshi Kamlesh Joshi
Reply | Threaded
Open this post in threaded view
|

RE: [External]Re: Ignite cluster became unresponsive

Thanks for the findings Ilya.

 

So shall we set the same timeout value for socketWriteTimeout as that of failure detection timeout on both client and server side?

 

 

Thanks and Regards,

Kamlesh Joshi

 

From: Ilya Kasnacheev <[hidden email]>
Sent: 10 July 2020 19:48
To: [hidden email]
Subject: Re: [External]Re: Ignite cluster became unresponsive

 

The e-mail below is from an external source. Please do not open attachments or click links from an unknown or suspicious origin.

Hello!

 

It seems that communication connections were closed after CG pause, then you have got half-open connections. It is recommended to keep socketWriteTimeout and failure detection timeout in relative sync.

 

Default socketWriteTimeout on TcpConnectionSpi is very low while your failure detection timeout is rather high, leading to such issue.

 

It is also possible that client nodes can connect to a server node but not vice versa, leading to failure of opening connections once they are closed:

 

Thread [name="sys-stripe-12-#13%EDIFCustomerCC%", id=45, state=RUNNABLE, blockCnt=851, waitCnt=27526057]
        at sun.nio.ch.Net.poll(Native Method)
        at sun.nio.ch.SocketChannelImpl.poll(SocketChannelImpl.java:954)
        at sun.nio.ch.SocketAdaptor.connect(SocketAdaptor.java:110)
        at o.a.i.spi.communication.tcp.TcpCommunicationSpi.createTcpClient(TcpCommunicationSpi.java:3299)
        at o.a.i.spi.communication.tcp.TcpCommunicationSpi.createNioClient(TcpCommunicationSpi.java:2987)
        at o.a.i.spi.communication.tcp.TcpCommunicationSpi.reserveClient(TcpCommunicationSpi.java:2870)
        at o.a.i.spi.communication.tcp.TcpCommunicationSpi.sendMessage0(TcpCommunicationSpi.java:2713)
        at o.a.i.spi.communication.tcp.TcpCommunicationSpi.sendMessage(TcpCommunicationSpi.java:2672)

 

Regards,

--

Ilya Kasnacheev

 

 

пт, 10 июл. 2020 г. в 16:32, Kamlesh Joshi <[hidden email]>:

Hi Ilya,

 

PFA the entire node logs, which contains thread dump as well. Let us know if any findings.

 

Thanks and Regards,

Kamlesh Joshi

 

From: Ilya Kasnacheev <[hidden email]>
Sent: 10 July 2020 17:51
To: [hidden email]
Subject: Re: [External]Re: Ignite cluster became unresponsive

 

The e-mail below is from an external source. Please do not open attachments or click links from an unknown or suspicious origin.

Hello!

 

Can you provide full thread dump (jstack) after you see these messages?

 

Regards,

--

Ilya Kasnacheev

 

 

ср, 8 июл. 2020 г. в 15:57, Kamlesh Joshi <[hidden email]>:

Hi Stephen/Team,

 

Did you got any chance to look into this?

 

Thanks and Regards,

Kamlesh Joshi

 

From: Kamlesh Joshi
Sent: 06 July 2020 14:50
To: [hidden email]
Subject: RE: [External]Re: Ignite cluster became unresponsive

 

Hi Stephen,

 

We have started our node with below JVM parameters. Also, we have increased these timeouts failureDetectionTimeout/clientFailureDetectionTimeout/networkTimeout to 480000.

 

-XX:+AggressiveOpts -XX:+AlwaysPreTouch -XX:+UseG1GC -XX:+ScavengeBeforeFullGC -XX:+DisableExplicitGC -XX:+UnlockCommercialFeatures -Djava.net.preferIPv4Stack=true -DIGNITE_LONG_OPERATIONS_DUMP_TIMEOUT=600000 -DIGNITE_THREAD_DUMP_ON_EXCHANGE_TIMEOUT=true -Dfile.encoding=UTF-8 -DIGNITE_QUIET=false

 

Is there anything else that we have to tune ?

 

And I think JVM pause is introduced as a result of the error that we encountered right? Correct me if am wrong.

 

Thanks and Regards,

Kamlesh Joshi

 

From: Stephen Darlington <[hidden email]>
Sent: 06 July 2020 14:09
To: user <[hidden email]>
Subject: [External]Re: Ignite cluster became unresponsive

 

The e-mail below is from an external source. Please do not open attachments or click links from an unknown or suspicious origin.

There are a few issues here — the blocked thread, the communication error — but I possibly the key one is the JVM pause:

 

[2020-07-03T18:17:21,793][WARN ][jvm-pause-detector-worker][IgniteKernal%CustomerCC] Possible too long JVM pause: 10133 milliseconds.

 

This is usually due to garbage collection, but there are a number of other possibilities such as slow I/O. Suggest you start with the recommendations on the GC tuning documentation page: https://apacheignite.readme.io/docs/jvm-and-system-tuning

 

Regards,

Stephen

 

On 4 Jul 2020, at 12:44, Kamlesh Joshi <[hidden email]> wrote:

 

Hi Team,

 

We have encountered following defect in PROD environment. After which entire traffic got halted for around 10 minutes, we recently upgraded our cluster to Ignite 2.7.6 from 2.6.0. 

Is this related to any existing open defect in this version? Has anyone observed the same defect earlier ?

 

Any help or pointers around this will be appreciated.

 

 

[2020-07-03T18:17:11,613][ERROR][sys-stripe-36-#37%CustomerCC%][G] Blocked system-critical thread has been detected. This can lead to cluster-wide undefined behaviour

[threadName=partition-exchanger, blockedFor=480s]

[2020-07-03T18:17:11,613][WARN ][sys-stripe-36-#37%CustomerCC%][G] Thread [name="exchange-worker-#344%CustomerCC%", id=391, state=TIMED_WAITING, blockCnt=1, waitCnt=2049782]

    Lock [object=java.util.concurrent.locks.AbstractQueuedSynchronizer$ConditionObject@6bf9f3a4, ownerName=null, ownerId=-1]

 

[2020-07-03T18:17:11,620][ERROR][sys-stripe-36-#37%CustomerCC%][] Critical system error detected. Will be handled accordingly to configured handler [hnd=StopNodeOrHaltFailureHandler [tryStop=false, timeout=0, super=AbstractFailureHandler [ignoredFailureTypes=[SYSTEM_WORKER_BLOCKED, SYSTEM_CRITICAL_OPERATION_TIMEOUT]]], failureCtx=FailureContext [type=SYSTEM_WORKER_BLOCKED, err=class o.a.i.IgniteException: GridWorker [name=partition-exchanger, igniteInstanceName=CustomerCC, finished=false, heartbeatTs=1593780431612]]]

org.apache.ignite.IgniteException: GridWorker [name=partition-exchanger, igniteInstanceName=CustomerCC, finished=false, heartbeatTs=1593780431612]

    at org.apache.ignite.internal.IgnitionEx$IgniteNamedInstance$2.apply(IgnitionEx.java:1831) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.IgnitionEx$IgniteNamedInstance$2.apply(IgnitionEx.java:1826) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.worker.WorkersRegistry.onIdle(WorkersRegistry.java:233) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.util.worker.GridWorker.onIdle(GridWorker.java:297) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.util.StripedExecutor$Stripe.body(StripedExecutor.java:513) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.util.worker.GridWorker.run(GridWorker.java:120) [ignite-core-2.7.6.jar:2.7.6]

    at java.lang.Thread.run(Thread.java:748) [?:1.8.0_151]

[2020-07-03T18:17:11,625][WARN ][sys-stripe-36-#37%CustomerCC%][FailureProcessor] No deadlocked threads detected.

[2020-07-03T18:17:21,790][INFO ][tcp-disco-sock-reader-#201%CustomerCC%][TcpDiscoverySpi] Finished serving remote node connection [rmtAddr=/xx.xx.xx.xx:46416, rmtPort=46416

[2020-07-03T18:17:21,793][WARN ][jvm-pause-detector-worker][IgniteKernal%CustomerCC] Possible too long JVM pause: 10133 milliseconds.

    [2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-31-#295%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:11764, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-57-#321%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:38500, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-5-#269%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:41442, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-53-#317%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:44178, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-59-#323%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:11884, writeTimeout=2000]

[2020-07-03T18:17:21,795][WARN ][grid-nio-worker-tcp-comm-59-#323%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:39044, writeTimeout=2000]

[2020-07-03T18:17:21,795][WARN ][grid-nio-worker-tcp-comm-53-#317%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:48756, writeTimeout=2000]

[2020-07-03T18:17:21,795][WARN ][grid-nio-worker-tcp-comm-59-#323%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:42190, writeTimeout=2000]

 

 

 

 

 

Thanks and Regards,

Kamlesh Joshi

 


"Confidentiality Warning: This message and any attachments are intended only for the use of the intended recipient(s), are confidential and may be privileged. If you are not the intended recipient, you are hereby notified that any review, re-transmission, conversion to hard copy, copying, circulation or other use of this message and any attachments is strictly prohibited. If you are not the intended recipient, please notify the sender immediately by return email and delete this message and any attachments from your system.

Virus Warning: Although the company has taken reasonable precautions to ensure no viruses are present in this email. The company cannot accept responsibility for any loss or damage arising from the use of this email or attachment."

 


"Confidentiality Warning: This message and any attachments are intended only for the use of the intended recipient(s), are confidential and may be privileged. If you are not the intended recipient, you are hereby notified that any review, re-transmission, conversion to hard copy, copying, circulation or other use of this message and any attachments is strictly prohibited. If you are not the intended recipient, please notify the sender immediately by return email and delete this message and any attachments from your system.

Virus Warning: Although the company has taken reasonable precautions to ensure no viruses are present in this email. The company cannot accept responsibility for any loss or damage arising from the use of this email or attachment."


"Confidentiality Warning: This message and any attachments are intended only for the use of the intended recipient(s), are confidential and may be privileged. If you are not the intended recipient, you are hereby notified that any review, re-transmission, conversion to hard copy, copying, circulation or other use of this message and any attachments is strictly prohibited. If you are not the intended recipient, please notify the sender immediately by return email and delete this message and any attachments from your system.

Virus Warning: Although the company has taken reasonable precautions to ensure no viruses are present in this email. The company cannot accept responsibility for any loss or damage arising from the use of this email or attachment."


"Confidentiality Warning: This message and any attachments are intended only for the use of the intended recipient(s), are confidential and may be privileged. If you are not the intended recipient, you are hereby notified that any review, re-transmission, conversion to hard copy, copying, circulation or other use of this message and any attachments is strictly prohibited. If you are not the intended recipient, please notify the sender immediately by return email and delete this message and any attachments from your system.

Virus Warning: Although the company has taken reasonable precautions to ensure no viruses are present in this email. The company cannot accept responsibility for any loss or damage arising from the use of this email or attachment."

ilya.kasnacheev ilya.kasnacheev
Reply | Threaded
Open this post in threaded view
|

Re: [External]Re: Ignite cluster became unresponsive

Hello!

I recommend setting it somewhat lower, but longer than any of your expected GC pauses. 30s is OK.

Regards,
--
Ilya Kasnacheev


вс, 12 июл. 2020 г. в 14:03, Kamlesh Joshi <[hidden email]>:

Thanks for the findings Ilya.

 

So shall we set the same timeout value for socketWriteTimeout as that of failure detection timeout on both client and server side?

 

 

Thanks and Regards,

Kamlesh Joshi

 

From: Ilya Kasnacheev <[hidden email]>
Sent: 10 July 2020 19:48
To: [hidden email]
Subject: Re: [External]Re: Ignite cluster became unresponsive

 

The e-mail below is from an external source. Please do not open attachments or click links from an unknown or suspicious origin.

Hello!

 

It seems that communication connections were closed after CG pause, then you have got half-open connections. It is recommended to keep socketWriteTimeout and failure detection timeout in relative sync.

 

Default socketWriteTimeout on TcpConnectionSpi is very low while your failure detection timeout is rather high, leading to such issue.

 

It is also possible that client nodes can connect to a server node but not vice versa, leading to failure of opening connections once they are closed:

 

Thread [name="sys-stripe-12-#13%EDIFCustomerCC%", id=45, state=RUNNABLE, blockCnt=851, waitCnt=27526057]
        at sun.nio.ch.Net.poll(Native Method)
        at sun.nio.ch.SocketChannelImpl.poll(SocketChannelImpl.java:954)
        at sun.nio.ch.SocketAdaptor.connect(SocketAdaptor.java:110)
        at o.a.i.spi.communication.tcp.TcpCommunicationSpi.createTcpClient(TcpCommunicationSpi.java:3299)
        at o.a.i.spi.communication.tcp.TcpCommunicationSpi.createNioClient(TcpCommunicationSpi.java:2987)
        at o.a.i.spi.communication.tcp.TcpCommunicationSpi.reserveClient(TcpCommunicationSpi.java:2870)
        at o.a.i.spi.communication.tcp.TcpCommunicationSpi.sendMessage0(TcpCommunicationSpi.java:2713)
        at o.a.i.spi.communication.tcp.TcpCommunicationSpi.sendMessage(TcpCommunicationSpi.java:2672)

 

Regards,

--

Ilya Kasnacheev

 

 

пт, 10 июл. 2020 г. в 16:32, Kamlesh Joshi <[hidden email]>:

Hi Ilya,

 

PFA the entire node logs, which contains thread dump as well. Let us know if any findings.

 

Thanks and Regards,

Kamlesh Joshi

 

From: Ilya Kasnacheev <[hidden email]>
Sent: 10 July 2020 17:51
To: [hidden email]
Subject: Re: [External]Re: Ignite cluster became unresponsive

 

The e-mail below is from an external source. Please do not open attachments or click links from an unknown or suspicious origin.

Hello!

 

Can you provide full thread dump (jstack) after you see these messages?

 

Regards,

--

Ilya Kasnacheev

 

 

ср, 8 июл. 2020 г. в 15:57, Kamlesh Joshi <[hidden email]>:

Hi Stephen/Team,

 

Did you got any chance to look into this?

 

Thanks and Regards,

Kamlesh Joshi

 

From: Kamlesh Joshi
Sent: 06 July 2020 14:50
To: [hidden email]
Subject: RE: [External]Re: Ignite cluster became unresponsive

 

Hi Stephen,

 

We have started our node with below JVM parameters. Also, we have increased these timeouts failureDetectionTimeout/clientFailureDetectionTimeout/networkTimeout to 480000.

 

-XX:+AggressiveOpts -XX:+AlwaysPreTouch -XX:+UseG1GC -XX:+ScavengeBeforeFullGC -XX:+DisableExplicitGC -XX:+UnlockCommercialFeatures -Djava.net.preferIPv4Stack=true -DIGNITE_LONG_OPERATIONS_DUMP_TIMEOUT=600000 -DIGNITE_THREAD_DUMP_ON_EXCHANGE_TIMEOUT=true -Dfile.encoding=UTF-8 -DIGNITE_QUIET=false

 

Is there anything else that we have to tune ?

 

And I think JVM pause is introduced as a result of the error that we encountered right? Correct me if am wrong.

 

Thanks and Regards,

Kamlesh Joshi

 

From: Stephen Darlington <[hidden email]>
Sent: 06 July 2020 14:09
To: user <[hidden email]>
Subject: [External]Re: Ignite cluster became unresponsive

 

The e-mail below is from an external source. Please do not open attachments or click links from an unknown or suspicious origin.

There are a few issues here — the blocked thread, the communication error — but I possibly the key one is the JVM pause:

 

[2020-07-03T18:17:21,793][WARN ][jvm-pause-detector-worker][IgniteKernal%CustomerCC] Possible too long JVM pause: 10133 milliseconds.

 

This is usually due to garbage collection, but there are a number of other possibilities such as slow I/O. Suggest you start with the recommendations on the GC tuning documentation page: https://apacheignite.readme.io/docs/jvm-and-system-tuning

 

Regards,

Stephen

 

On 4 Jul 2020, at 12:44, Kamlesh Joshi <[hidden email]> wrote:

 

Hi Team,

 

We have encountered following defect in PROD environment. After which entire traffic got halted for around 10 minutes, we recently upgraded our cluster to Ignite 2.7.6 from 2.6.0. 

Is this related to any existing open defect in this version? Has anyone observed the same defect earlier ?

 

Any help or pointers around this will be appreciated.

 

 

[2020-07-03T18:17:11,613][ERROR][sys-stripe-36-#37%CustomerCC%][G] Blocked system-critical thread has been detected. This can lead to cluster-wide undefined behaviour

[threadName=partition-exchanger, blockedFor=480s]

[2020-07-03T18:17:11,613][WARN ][sys-stripe-36-#37%CustomerCC%][G] Thread [name="exchange-worker-#344%CustomerCC%", id=391, state=TIMED_WAITING, blockCnt=1, waitCnt=2049782]

    Lock [object=java.util.concurrent.locks.AbstractQueuedSynchronizer$ConditionObject@6bf9f3a4, ownerName=null, ownerId=-1]

 

[2020-07-03T18:17:11,620][ERROR][sys-stripe-36-#37%CustomerCC%][] Critical system error detected. Will be handled accordingly to configured handler [hnd=StopNodeOrHaltFailureHandler [tryStop=false, timeout=0, super=AbstractFailureHandler [ignoredFailureTypes=[SYSTEM_WORKER_BLOCKED, SYSTEM_CRITICAL_OPERATION_TIMEOUT]]], failureCtx=FailureContext [type=SYSTEM_WORKER_BLOCKED, err=class o.a.i.IgniteException: GridWorker [name=partition-exchanger, igniteInstanceName=CustomerCC, finished=false, heartbeatTs=1593780431612]]]

org.apache.ignite.IgniteException: GridWorker [name=partition-exchanger, igniteInstanceName=CustomerCC, finished=false, heartbeatTs=1593780431612]

    at org.apache.ignite.internal.IgnitionEx$IgniteNamedInstance$2.apply(IgnitionEx.java:1831) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.IgnitionEx$IgniteNamedInstance$2.apply(IgnitionEx.java:1826) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.worker.WorkersRegistry.onIdle(WorkersRegistry.java:233) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.util.worker.GridWorker.onIdle(GridWorker.java:297) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.util.StripedExecutor$Stripe.body(StripedExecutor.java:513) [ignite-core-2.7.6.jar:2.7.6]

    at org.apache.ignite.internal.util.worker.GridWorker.run(GridWorker.java:120) [ignite-core-2.7.6.jar:2.7.6]

    at java.lang.Thread.run(Thread.java:748) [?:1.8.0_151]

[2020-07-03T18:17:11,625][WARN ][sys-stripe-36-#37%CustomerCC%][FailureProcessor] No deadlocked threads detected.

[2020-07-03T18:17:21,790][INFO ][tcp-disco-sock-reader-#201%CustomerCC%][TcpDiscoverySpi] Finished serving remote node connection [rmtAddr=/xx.xx.xx.xx:46416, rmtPort=46416

[2020-07-03T18:17:21,793][WARN ][jvm-pause-detector-worker][IgniteKernal%CustomerCC] Possible too long JVM pause: 10133 milliseconds.

    [2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-31-#295%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:11764, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-57-#321%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:38500, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-5-#269%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:41442, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-53-#317%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:44178, writeTimeout=2000]

[2020-07-03T18:17:21,794][WARN ][grid-nio-worker-tcp-comm-59-#323%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:11884, writeTimeout=2000]

[2020-07-03T18:17:21,795][WARN ][grid-nio-worker-tcp-comm-59-#323%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:39044, writeTimeout=2000]

[2020-07-03T18:17:21,795][WARN ][grid-nio-worker-tcp-comm-53-#317%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:48756, writeTimeout=2000]

[2020-07-03T18:17:21,795][WARN ][grid-nio-worker-tcp-comm-59-#323%CustomerCC%][TcpCommunicationSpi] Communication SPI session write timed out (consider increasing 'socketWriteTimeout' configuration property) [remoteAddr=/xx.xx.xx.xx:42190, writeTimeout=2000]

 

 

 

 

 

Thanks and Regards,

Kamlesh Joshi

 


"Confidentiality Warning: This message and any attachments are intended only for the use of the intended recipient(s), are confidential and may be privileged. If you are not the intended recipient, you are hereby notified that any review, re-transmission, conversion to hard copy, copying, circulation or other use of this message and any attachments is strictly prohibited. If you are not the intended recipient, please notify the sender immediately by return email and delete this message and any attachments from your system.

Virus Warning: Although the company has taken reasonable precautions to ensure no viruses are present in this email. The company cannot accept responsibility for any loss or damage arising from the use of this email or attachment."

 


"Confidentiality Warning: This message and any attachments are intended only for the use of the intended recipient(s), are confidential and may be privileged. If you are not the intended recipient, you are hereby notified that any review, re-transmission, conversion to hard copy, copying, circulation or other use of this message and any attachments is strictly prohibited. If you are not the intended recipient, please notify the sender immediately by return email and delete this message and any attachments from your system.

Virus Warning: Although the company has taken reasonable precautions to ensure no viruses are present in this email. The company cannot accept responsibility for any loss or damage arising from the use of this email or attachment."


"Confidentiality Warning: This message and any attachments are intended only for the use of the intended recipient(s), are confidential and may be privileged. If you are not the intended recipient, you are hereby notified that any review, re-transmission, conversion to hard copy, copying, circulation or other use of this message and any attachments is strictly prohibited. If you are not the intended recipient, please notify the sender immediately by return email and delete this message and any attachments from your system.

Virus Warning: Although the company has taken reasonable precautions to ensure no viruses are present in this email. The company cannot accept responsibility for any loss or damage arising from the use of this email or attachment."


"Confidentiality Warning: This message and any attachments are intended only for the use of the intended recipient(s), are confidential and may be privileged. If you are not the intended recipient, you are hereby notified that any review, re-transmission, conversion to hard copy, copying, circulation or other use of this message and any attachments is strictly prohibited. If you are not the intended recipient, please notify the sender immediately by return email and delete this message and any attachments from your system.

Virus Warning: Although the company has taken reasonable precautions to ensure no viruses are present in this email. The company cannot accept responsibility for any loss or damage arising from the use of this email or attachment."